background image

Manual edition  V1.1 

AXEL installation  

Page   

Contents

 

 

Description & specifications 

Responsibilities & consideration 

Gate mounting 

Driveway layout 

Groundwork & cable ducts 

Pier design & fitting 

Control panel wiring 

Commissioning 

8       User instructions 
9     Safety record & tutorial 
11     Warranty 

 

 

Description 

 

 

AXEL sets are suitable for prestige estate gates. The 
powerful  PWM  motors  have  internal  encoders  to 
monitor gate position. Stall sensors detect obstacles 
and  in  order  to  reverse  the  gate’s  direction.  Speed 
and pressure are adjusted in compliance with safety 
standards.    AXEL  sets  are  safe  and  green.  They  will 
provide long and reliable service if fitted and main-
tained according to the instructions in this manual. 

 

Remotes  use  a  ‘Rolling  Code’  format  that  changes 
the code sent every time it is used. It can’t be cop-
ied, keeping your home secure.  
A key operated manual release 
mechanism  allows  access  in 
case of a power outage.  

 

Though this equipment is com-
plex,  user  programming  has 
been  kept  simple.  Foresee 
have  a  planned  program  of 
simple hi technology new prod-
uct releases to keep your home 
secure and up to date.  

Technical Specifications 

  Supply volt-
age 

  220-240Vac 

 Motor power 

  100W @ 
24Vdc 

  Supply rating 

 2.5A @ 50-
60Hz 

 Motor torque    250Nm max 

  Standby 
power 

  <10W 

 Motor insula-
tion 

  IP67 

  Ambient 
temp 

 -20° to +70° 

Open angle 

  100 degrees 

  Remotes 

 433MHz  
50max 

Opening speed    4.5° /sec 

  Duty cycle 

  60% 

Max leaf size   2.5m wide, 5m

²

 

area 

  Noise 

  <70 dB 

Max leaf  500kgm  (weight x 
width) 

Set contents 

 

 

AK-424

      The  standard  set  is  for  double  leaf 

boarded  gates,  and  heavy  domestic  gates.  The 
set  includes  two  underground  openers,  control 
panel,  two  remotes  and  a  photo-beam.    RIO-X 
control panel requires a 230Vac supply.  

 

AK-414

   This single leaf version is approved for 

gates  leaves  up  to  2.8m  when  installed  with  an 
electric lock (not included) or pedestrian gates. 

 

AL-424

   This is the AXEL low power set. The RIO-

XL  control  panel  is  powered  by  an  ELV  source 
mounted remotely, often in the house or garage. 
RIO-XL  includes  1.1Ahr  batteries.  Ideal  for  sites 
where  a  long  mains  cable  would  be  difficult  or 
expensive to run. The charging cable can also be 
used for an intercom or other controls.  

 

All  sets  include  two  remotes  and  a  photobeam 
set.  Mains  powered  sets  can  be  fitted  with  the 
battery  backup  set  for  up  to  10  hours  off  grid. 
Without  batteries,  gates  will  attempt  to  close 
when power is restored.  

 

Set  contents  are  a  starting  point.  Additional 
devices  may  be  added.  Further  safety  devices 
may be required. Mains isolator is not included  

Содержание AXEL F730

Страница 1: ...www forematic com Underground gate opener AXEL AXEL F730 installation...

Страница 2: ...nd up to date Technical Specifications Supply volt age 220 240Vac Motor power 100W 24Vdc Supply rating 2 5A 50 60Hz Motor torque 250Nm max Standby power 10W Motor insula tion IP67 Ambient temp 20 to 7...

Страница 3: ...compliance that ensure the gate is safe to users and public Automatic gate signs are required on both sides of the gate warning against risk of contact injury The installer must prepare a handover pac...

Страница 4: ...s The most common D requires the gate to be off centre and therefore will require a safety edge to protect the pinch hazard E is on centre but leaves a sight gap or you need to cope with a rear hung g...

Страница 5: ...ently fill the casement then fill the soakaway Consider a surface drain Wood swells when it absorbs moisture A gap between gate boards and between gate leaves is essential Any sight gap between leaves...

Страница 6: ...or with steel post reinforcement That is a decision beyond the scope of this manual Two concrete bases are required for the piers set at precisely the same level Level off 170mm below road level to g...

Страница 7: ...ss control it is normally fitted to the left pier because that is the side visitors get out of their vehicles Height is typically 1 5m Leave a suitable duct access hole Ducts will run either to the co...

Страница 8: ...you need the gate to open less you can fit an addition ground stop Fit the stub axle plate and stop plate over the exposed studs in the upper shelf then fix with the locking nuts Fig 12b Motor arms M...

Страница 9: ...ter the panel through glands Running the cables behind the PCB keeps the limited space tidy It is better to hide cables than cut them too short Mark all cables The wiring plan below shows individual c...

Страница 10: ...Move the green wire to D for single leaf door opening Remotes can be set for these two functions See user instructions SAFETY DEVICES F C or E C There two inputs are for safety devices Input F preven...

Страница 11: ...o work during the day could be viable free entry device for a commercial property Keypads are useful for friends family or trusted delivery drivers This keypad can accept many codes and some for singl...

Страница 12: ...hinge position is on the pier corner so finger traps are less likely Fig21 An safety edge has been added to the gate leaf that closes last There are now two devices on F wired as Fig26 or Fig27 Fig22...

Страница 13: ...nd of the gate E or F power Beam Fig 27 One DRI edge on on a pier power Beam Fig 28 Wiring 2 DRI s Yellow NC Blue Com Black Gnd Red Supply power Open Timer A wired switch or timer can hold a gate open...

Страница 14: ...y 100 010 110 001 101 011 111 5s 15s 20s 60s 65s 75s 80s Delay 2s 3s 4s 5s DIP 1 2 opening 00 10 01 11 DIP 3 4 closing 00 10 01 11 PCB buttons There are two buttons on the PCB The CODE button is used...

Страница 15: ...ial for force test limits The safe force limits need to be observed Adjusting the first 3 settings will help comply The adjustments above should not affect the limit learning Small changes in physical...

Страница 16: ...p to maintain safety Our website PICO support page has fault finding support You can save up to 50 remotes There are two remote channels Pedestrian channel opens one gate only Main opens both You will...

Страница 17: ...ords Activation Input Position Device code G Fault finding There are 8 LED s on RIO X that show the states of inputs and the gate position Gate runs slowly This happens when there has been a loss of p...

Страница 18: ...de of Practice can be found at www dhfonline org uk Force testing EN12445 explains the method of testing the impact forces of a gate The crux is a graph of acceptable forces from the point of impact S...