Operating Manual BKS601C
45
10.6
Configuration
The configuration defines how many process data (byte and word) are sent during the
cyclic communication from the control system to the web guide controller and from
the web guide controller to the control system.
To ensure maximum flexibility using the web guide controller, there are different
modules supplied in a single web guide controller only one module can be set active at
a time.
Module 1: Basic telegram
4 bytes (2 word) re transmitted from the control system to the web guide controller
and also 4 bytes (2 word) from the web guide controller to the control system in each
data cycle.
byte 0
byte 1
byte 2
byte 3
request telegram
(master
→
slave)
function
code
module
number
empty empty
response telegram
(slave
→
master)
function
code
module
number
data (higher
byte)
data (lower
byte)
Modul 2: Reserved
Modul 3: Basic telegram and 4 word operation value (CMGZ611A, CMGZ630A)
The web guide controller responses with 4 bytes of the basic telegram and the 4 word
(feedback, reference, control error, output per channel).
Byte 0
Byte 1
Byte 2
Byte 3
request telegram
(master
→
slave)
function
code
module
number
empty empty
response telegram
(slave
→
master)
function
code
module
number
data (higher
byte)
data (lower
byte)
Word 0
Word 1
Feedback Reference
(HB)/(LB) (HB)/(LB)
10.7
Function Code
Master
→
Slave
Function Values
Value
Meaning
Remarks
01h
Feedback
feedback tension controller
02h
Reference
reference tension controller