Operating Manual BKS601C
32
9.4
Description of the System Parameters
The mode for parameter changing is activated by pressing the
PARA
↵
key for 3
seconds. By pressing the
PARA
↵
key again, the system parameters are selected (see
Fig. 22
).
Language
Use:
This parameter determines the display language.
Range:
English, French, Italian, German
Measuring system
Use:
This parameter determines the measuring system that will be used.
Range:
Metric, US standard
Default:
Metric
Note:
(not used from the BKS601C)
Lowpass display
Use:
The electronic unit has a build-in lowpass filter that filters noise which
might interfere with the display signal. The filter improves the reading
by making the display more stable against highly fluctuating force
values. This parameter determines the cut off frequency. The lower
the cut off frequency, the more sluggish the output signal will be. The
lowpass display filter is independent from the other filters.
Range:
0.1
to
10.0
Default:
1.0
Increment:
0.1
Unit:
[Hz]
Identifier
Use:
This parameter is used to identify the device in a PROFIBUS
interface network.
Range:
2
to
125
Default:
84
Increment:
1
Unit:
[-]