Operating Manual BKS601C
34
Digital input 3
Use:
Identical
with
Digital input 1
but the parameter acts to the digital
input 3.
Digital input 4
Use:
Identical
with
Digital input 1
but the parameter acts to the digital
input 4.
Digital output 1
Use:
This parameter defines at which event the digital output 1 shell be
activated.
Range:
Automatic OK, Centre pos, Detection OK, Edge missing,
Definition:
Automatic OK:
Controller is active; edge is read
Edge missing:
No edge found during detection run
Detection OK:
Detection was successful; an edge was
found.
Digital output 2
Use:
Identical
with
Digital output 1
but the parameter acts to the digital
output 2.
Base distance left
Use:
This parameter stores the distance between reference point on the
machine frame and the reference point of the left linear unit.
Range:
0.0
to
3200.0
Default:
0.0
Increment:
0.1
Unit:
[mm]
Base distance right
Use:
Identical
with
base distance left
but the parameter refers to the
reference point of the right linear unit.
Analog output
Use:
This parameter defines the signal that will be read-out at the analog
output. With the option
control output,
an actuator with analog
signal can be operated. Instead of an FMS steering frame e.g. a.
hydraulic valve can then be used (see parameter
Configuration
output
). With the option
Feedback Sensor
, the current web position
is sent to the output (during automatic operation).
Range:
Feedback Sensor, Control Output
Default:
Feedback
Sensor