Operating Manual BKS601C
42
Left Sensor covered
Use:
The
parameters
Sensor covered
,
Sensor uncovered
and
Sensor range
determine the scaling of any sensor signal. In this case, the signal of
the covered left sensor is stored.
Range:
0.000 to
10.000
Default:
0.000
Increment:
0.001
Unit:
[V]
Left Sensor uncovered
Use:
The signal of the uncovered left sensor is stored.
Range:
0.000 to
10.000
Default:
10.000
Increment:
0.001
Unit:
[V]
Left Sensor range
Use:
The left sensor detection range is stored.
Range:
0.00
to
100.00
Default:
10.00
Increment:
0.01
Unit:
[mm]
Right Sensor covered
Use:
The
parameters
Sensor covered
,
Sensor uncovered
and
Sensor range
determine the scaling of any sensor signal. In this case, the signal of
the covered right sensor is stored.
Range:
0.000 to
10.000
Default:
0.000
Increment:
0.001
Unit:
[V]
Right Sensor uncovered
Use:
The signal of the uncovered right sensor is stored.
Range:
0.000 to
10.000
Default:
10.000
Increment:
0.001
Unit:
[V]
Right Sensor range
Use:
The right sensor detection range is stored.
Range:
0.00
to
100.00
Default:
10.00
Increment:
0.01
Unit:
[mm]