![background image](http://html1.mh-extra.com/html/flysky/noble-pro/noble-pro_user-manual_2312267026.webp)
Pro
Website
22
Channel speed - Front/Throttle
This function is used to set the delay of the throttle start and return-to-center.
[Start]: sets the speed of throttle acceleration.
[Return to center]: sets the speed at which the throttle returns to the center position.
[Point P1]: means the division point between the first forward travel and the second forward travel. The default
point is 30%, and adjustable range is 0-99%.
[Point P2]: means the division point between the second forward travel and the third forward travel. The default
point is 60%, and the adjustable range is 1-100%.
[L]: the first travel.
[M]: the second travel. It can be set under the menu of mode 2 and mode 3.
[H]: the third travel. It can be set under the menu of mode 3.
Setup:
1. Click the icon on the right side of [Mode]. Click the "+" or "-" icon to switch to the desired mode.
2. Click the option that needs to be set. This item is highlighted when selected.
3. Click the "+" or "-" icon to change the response time or the percentage of the corresponding point as required.
Press the "+" or "-" icon to accelerate adjustment of the corresponding value.
The percentage of point P1 differs from the percentage of point P2 by at least 1%.
The lower the percentage, the slower the throttle channel responding to the throttle trigger operation.
4. Verify the settings are normal as expected.
Channel Speed - CH3-CH18
This function is used to set the delay time of CH3-CH18 forward and return-to-center.