PG9602™ OPERATION AND MAINTENANCE MANUAL
© 2011 Fluke Calibration
Page
122
COMMAND
DESCRIPTION
DIFLOAD
Execute the mass load determined by the DIFSETUP command
DIFOFFSET(=)
Read or set the differential mode RPM offset value
DIFSETUP
Prepare PG7601 to determine the differential mode RPM offset
DUTHEIGHT(=)
Set or read the DUT head height
ERR
Read the last error message
LOCALG(=)
Set or read the local gravity
LOCAL
Local operation
MASSSETx(=)
Set or read the mass set values
MASSx(=)
Set or read the mass set data
MASS(=)
Set or read the selected mass set
MEDIA(=)
Set or read the DUT head medium
MEM
Read the memory OK flag
MMODE(=)
Set or read the measurement mode
MRES(=)
Set or read the mass loading resolution
MROT(=)
Set or read the manual motorized rotation status
MR
Read the current mass load
MS=
Specify a new mass target, loading masses if AMH enabled
OHMS
Read the ambient PRT and piston-cylinder PRT resistance
PASSTHRUx
Allow the host PC to communicate with a device connected to the PG9000 COM
ports.
PCTx(=)
Set or read the source for the piston-cylinder temp
PGEN(=)
Set or read the automated pressure generation setting
PISTONRDYx(=)
Set or read piston rotation rate limits.
PISTONVARx(=)
Set or read additional piston variables
PISTONx(=)
Set or read the piston header information
PISTON(=)
Set or read the piston in use
PPC=
Send a command to an external pressure generation/control component.
PPCPR
Read the pressure measured by a PPC pressure controller connected to
PG9000’s COM3.
PPOS
Read the current piston position
PR
Read the current PG9000 defined pressure and “ready” status
PRTPCn
Set or read the piston cylinder temperature PRT information
PS=
Specify a new PG9000 target pressure, loading masses if AMH enabled
READYx(=)
Set or read the ready criteria for a specific “Setup”
READYCK(=)
Set or read the ready check flag status
REMOTE
Set the PG9000 into local lockout condition
RESET
Set basic PG9000 operating conditions to default. Equivalent to front panel
“Reset, Sets”.
RESUME
Resume the suspended process of setting a new pressure by remote command.
RESUME(=mode)
Set the resume mode, which determines whether a pressure setting process
initiated by remote command will pause after target entry and require the
RESUME command to continue .
SETUP(=)
Set or read the setup to use
SN
Read the PG9000 serial number
SPEED
Read the piston rotation speed
TIME(=)
Set or read the current time
UCOEF
Read the current pressure units conversion coefficient
UDD(=)
Set or read the user defined external barometer settings
UDU(=)
Set or read the user defined pressure unit
Содержание PG9000 Series
Страница 10: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page X Notes...
Страница 128: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 118 Notes...
Страница 164: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 154 Notes...
Страница 188: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 178 Notes...
Страница 192: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 182 Notes...