Getting Started
Connecting the OC3port Plus
2
2-19
Connecting the OC3port Plus to Network Devices
You need the appropriate type of cable to connect the OC3port Plus to network
devices. You can contact Fluke to obtain a variety of fiber optic and UTP cables.
Warning
Do not move the fiber connectors from side to side as you
insert them into the receptacles. Doing so can cause the
alignment ferrule to break.
1.
To receive signals from network devices, connect the fiber optic cable to the
OC3port Plus
IN
jack.
2.
To send signals on the line, connect the fiber optic cable to the OC3port Plus
OUT
jack.
To create a loopback situation, complete both steps.
Connecting to Remote Devices
The OC3port Plus provides two methods of making remote (RS-232) connections:
direct and modem. The direct method allows you to connect the OC3port Plus to a
PC. You can then use the PC to control the OC3port Plus or to print test results. If
you prefer this type of connection, the PC must have the appropriate software to
control these functions. Contact Fluke Corporation for a programming book or
information about the Testview package.
As an alternative, you can use the RS-232 line to connect the OC3port Plus to a
modem. After these connections are made, you must set the baud rate from the
OC3port Plus and change the communication settings from the receiving device.
Connecting the OC3port Plus to a PC or Laptop
To connect the OC3port Plus to a PC or laptop computer, do the following:
1.
Connect the RS-232 line to the OC3port Plus.
2.
Connect the other end to the computer serial port. If the computer has a DB-9
connector, use a DB-25-to-DB-9 converter.
3.
Turn on the OC3port Plus.
4.
Start the appropriate PC software.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com