OC3port Plus
User Manual
6-36
4. Press the
EDIT
key. You enter Edit mode. The number in the first position of
the
VPI MIN
field is flashing to indicate that Edit mode is active.
Press the arrow keys to supply a value for
VPI MIN
. When you finish, press
ENTER
to save the change.
5. Repeat Step 4 for each of the remaining
AUTO-SCAN
parameters.
You are finished setting up the search boundaries for the scan after you save
the value for
VCI MAX
.
Step Two: Set the Scan Rate
The scan rate determines the amount of time that the OC3port Plus spends
searching for individual addresses. This time can be adjusted to provide a,
relatively speaking, longer or shorter scan time. The value you specify determines
the minimum amount of time that traffic must arrive on a particular VPI/VCI
combination to be recorded.
Most scans take at least 30 seconds to complete. The more activity that is present
on a circuit and the slower the scan duration, the longer the actual time required to
complete a scan.
To select a scan rate, follow these steps:
1. Press the
AUTO
key. The
AUTO SELECTIONS
menu is displayed.
2. Press the
Down Arrow
key to move the ATM Activity Scan option to the
selection line. Then, press
ENTER
. The
ATM ACTIVITY SCAN
submenu is
displayed.
3.
Press the
Down Arrow
key to move the
Search Duration
option to the selection
line:
ATM ACTIVITY SCAN:
Act Detect Alarm OFF
Search Duration FST
Load Rcv Filters
za117f.eps