SONET/SDH Configuration and Testing
Generating Alarms
4
4-21
2.
Press the
Down Arrow
key to move the
View Alarm Log
option to the selection
line:
ALARM SELECTIONS
LOS Action MTN
View Alarm Log
- - - - - - - - - - - - - - - - - - - - - - -
za056f.eps
3.
Press
ENTER
. The alarm log is displayed. You see the first alarm listed in the
log, which looks similar to this:
SLOS 1 of 78
S: 03-20-99 11:27:46
E: 03-20-99 11:27:46
DURATION 1 Sec
za057f.eps
Line 1 of the display shows the type of alarm (in this example, SLOS) that was
detected and the number of this alarm (1 of 78) in the alarm log.
The alarm log uses the following prefixes to identify the type of alarm:
•
S
Indicates "Section".
For example, SLOS is a SECTION LOS alarm.
•
L
Indicates "Line".
For example, LAIS is a Line AIS alarm.
•
P
Indicates "Path".
For example, PYEL is a PATH YELLOW alarm.
An ATM Cell Lock alarm or cell delineation alarm is identified as
CELLD
in
the alarm log.