Testing ATM Networks
Monitoring an ATM Network
6
6-11
This display presents the cell reception rate in average cells per second (
AVER
CPS
).
Note
AVER CPS
is the average number of cells received per second since
the test began, since the filter was activated, or since the
CLEAR
key
was last pressed.
5.
Press the
Right Arrow
key again. Line 4 now shows you the bandwidth
statistics for the receive filter:
R1: CIRCUIT A
125 0016 PT0 CP1 G0
1.76E+09 C 353207CPS
BW:100% 100% 100%
za084f.eps
The bandwidth percentages provided represent the
MINIMUM <CURRENT
<MAXIMUM
bandwidth achieved since the test began, since the filter was
activated, or since the
CLEAR
key was last pressed.
6.
Press the
Up Arrow
key to view result displays for the remaining receive filters.
Note that if a receive filter is currently not active, you see a display similar to
this one:
R3: FILTER 3
255 1000 PTx CPx G0
NOT ACTIVE: PRESS
ENTER TO ACTIVATE
za085f.eps
Note
•
Only two of the four receive filters can be active at any one time.
•
To activate or de-activate a receive filter, press
ENTER
while
viewing that receive filter’s result display.