![Fluke OC3port Plus Скачать руководство пользователя страница 139](http://html.mh-extra.com/html/fluke/oc3port-plus/oc3port-plus_user-manual_2309945139.webp)
OC3port Plus
User Manual
6-8
To transmit OAM cells on a number of circuits at the same time, complete this
procedure for each transmission stream that you want to send OAM cells on.
Notes
The OAM parameters (for OAM Type and OAM Format) that are
used to construct the cell are programmable under the OAM
Transmit menu.
Selecting OAM as the payload modifies portions of the transmission
stream’s header (the VCI and PT fields), but this modification does
not show up in the setup options.
Multiple transmission streams can simultaneously have their payload
set to OAM. They all generate the same OAM cell, but with different
headers.
1.
Press the
ATM
key. The
ATM SELECTIONS
menu is displayed.
2.
Press the Down Arrow key to move the
Setup XMIT Streams
option to the
selection line. Press
ENTER
. The setup menu for one of the transmission
streams is displayed. For example:
TRANSMIT STREAM: 1
or for Change
NAME:XMITHDR_1
SOURCE CBR
za063f.eps
3.
Press the
Left
or
Right Arrow
key to display the transmission stream that you
want to use to transmit OAM cells.
4.
Press the
Down Arrow
key to move the
PAYLOAD
parameter to the selection
line:
TRANSMIT STREAM: 1
FIXED PAYLOAD:6A
PAYLOAD FIXED
CHECK SUM ON/OK
za067f.eps
5.
Press the
Left
or
Right Arrow
key to change the setting to OAM.
6.
Press the
ATM
key to return to the
ATM SELECTIONS
menu.