OC3port Plus
Users Manual
2-10
Table 2-3. SONET Alarms Detected by the OC3port Plus on the Status LEDs (cont.)
SONET Status LED
Description
PATH FERF
(Far End Receive Failure)
Dedicated when the 4
th
bit FEBE field within the Path
Status Byte (G1) is set to “1001” for two consecutive
frames.
If any other pattern is present for two consecutive
frames, a Path FERF alarm is removed.
PATH AIS
(Alarm Indication Signal)
Declared when an all-ones pattern is detected in the
pointer bytes (H1 and H2) for three consecutive STS-3c
frames.
A Path AIS alarm is removed whenever a valid pointer is
detected in H1 and H2 for three consecutive frames.
PATH YELLOW
Declared whenever bit 5 of the Path Status Byte (G1) is
set high (1) for five consecutive frames.
A path YELLOW alarm is removed when bit 5 returns
low (0) for five consecutive frames.
PATH LOSS OF POINTER
Declared whenever a normal pointer (generally values
within the 0 to 782 range) is not found in eight
consecutive frames.
Path Loss of Pointer is removed when a valid pointer is
detected for three consecutive frames.
A received Path AIS indication does not result in a Path
Loss of pointer alarm.
Negative and Positive stuff indications do not trigger a
Path Loss of Pointer alarm.
System Control Keys
The system control keys are located at the bottom of the tester.
You use these keys to control the entire unit; for example, to turn the OC3port Plus
on and off (
ON/OFF
key), to print configuration information and test results (
key), and to clear counters and delete alarms. (
CLEAR
key)