MDA-550/MDA-510
Users Manual
12
Display
The display shows the waveforms
as well as the
readings
that correspond to the selected measurement.
Figure 4. Measurement Screen
BWL
indicates that a bandwidth limiter (filter) is applied.
The filter is automatically selected for the specific
measurement.
AUTO
indicates that the Connect-and-View algorithm is
applied. The algorithm lets the test tool display complex
signals automatically. 1/2 AUTO indicates that the algorithm
is partially adapted for optimal results in the selected
function.
HOLD
shows on the display when you push
to
freeze the screen.
The Status Bar
shows the vertical range/division for each
active channel, the time/division, and the trigger channel.
The softkeys
correspond to the four function keys on the
Product. The labels and functions change according to the
menu that shows on the display.
Note
A warning message shows on the top left of the
display in Motor Drive Analysis mode to indicate
that bandwidth filters are automatically applied
on the input and that higher frequency
components of the signal are not measured.
1
2
3
4
5
6
HOLD
RUN