67
intelliRock technical support:
Visit www.flir.com/support or call (866) 276-8369, 9am - 5pm, EST
The 15 cylinders without intelliRock maturity loggers will be broken compressively in groups of three at
five different intervals, or as the project engineer directs.
BREAK THREE CYLINDERS
Each time a set of three cylinders is broken,
immediately
take the Current Reading from each of the
two cylinders containing intelliRock maturity loggers. This is done by connecting the logger wires to the
reader and the selecting F1: Current Reading options. Record the resulting strength and maturity
readings.
TAKE MATURITY READINGS
Using the intelliRock Strength Maturity Spreadsheet input the PSI information from each compressive
break and the corresponding maturity readings taken from the two intelliRock loggers. The spreadsheet
will take that information and plot the first point of the calibration curve.
IMPORTANT NOTE: Download the Strength Maturity Spreadsheet at
www.engius.com
.
Break Data
Maturity Data
Use the intelliRock cloud software to upload calibration data.
Содержание intelliRock III
Страница 1: ...intelliRock III Operating Instructions Guide...
Страница 4: ...4 intelliRock III Operating Instructions Guide...
Страница 40: ...40 intelliRock III Operating Instructions Guide...
Страница 65: ...65 intelliRock technical support Visit www flir com support or call 866 276 8369 9am 5pm EST Appendix...