22
intelliRock® III– Operating Instructions Guide
Figure 4.5 shows the logger setup screen for specifying a new job.
Figure 4.5: Setting a logger up for a new job.
The letters displayed in blue text in the center of the screen indicate which data-entry mode
the reader keyboard is in: text or numeric. Toggle between these modes the pressing the “Shift”
key. Using the reader keyboard:
1. Enter the desired job name.
2. Change the datum temperature if necessary by pressing F2 to increase it or F3 to de-
crease it. Regarding the datum temperature:
• The project engineer should provide the datum temperature.
• When the Nurse-Saul method is selected, datum temperature options are: 0 °C,
• -10 °C, or -20 °C.
• When the Arrhenius method is selected, datum temperature options are presented in
one °C increments.
3. Use the F4 key to select the method: Nurse-Saul, Arrhenius, or temperature.
Note:
unlike previous generations of the intelliRock system, which used different loggers
to support either the Nurse-Saul or Arrhenius maturity methods, both methods are
now supported by an intelliRock III maturity logger. Choose the method using the
setup process described above.
When logger setup is complete, press F1 to save the logger configuration, or F5 to abort setup
without saving. Pressing F1 to save the logger configuration will display the screen shown in
Figure 4.6.
Figure 4.6: Saving logger setup information.
Содержание intelliRock III
Страница 1: ...intelliRock III Operating Instructions Guide...
Страница 4: ...4 intelliRock III Operating Instructions Guide...
Страница 40: ...40 intelliRock III Operating Instructions Guide...
Страница 65: ...65 intelliRock technical support Visit www flir com support or call 866 276 8369 9am 5pm EST Appendix...