Maximum allowable transducer inaccuracy: +/-1.0 kPa
BioFlex 25mm Loading Station Static Performance (high side transducers):
Maximum allowable waveform variance from static line: +/- 0.25% elongation
Maximum % elongation error (actual vs. programmed): +/-0.5% elongation
Maximum allowable transducer inaccuracy: +/-2.0 kPa
BioFlex 25mm Loading Station Dynamic Performance (high side transducers):
Maximum % elongation error (actual vs. programmed): +/-0.75% elongation, at
the following frequencies: <15% elongation, 0.5 and 1.0 Hz; >17.5% elongation, 0.5Hz
Maximum allowable transducer inaccuracy: +/-2.0 kPa
L
OADING
S
TATIONS
™
S
PECIFICATIONS
BioFlex
®
25mm Diameter Loading Stations
™
(equibiaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 1.6%
Maximum achievable % elongation with the Flex Jr.
™
: 26.0%
StageFlexer
®
25mm Diameter Loading Stations
™
(equibiaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 1.6%
Maximum achievable % elongation with the Flex Jr.
™
: 14.8%
StageFlexer
®
28mm Diameter Loading Stations
™
(equibiaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 1.9%
Maximum achievable % elongation with the Flex Jr.
™
: 13.4%
StageFlexer
®
31mm Diameter Loading Stations
™
(equibiaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 2.1%
Maximum achievable % elongation with the Flex Jr.
™
: 8.6%
BioFlex
®
membrane with 18.5mm Diameter Loading Stations
™
(equibiaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 1.8%
Maximum achievable % elongation with the Flex Jr.
™
: 13.8%
Tissue Train
®
membrane with Arctangle
®
Loading Stations
™
(uniaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 2.5%
Maximum achievable % elongation with the Flex Jr.
™
: 17.7%
UniFlex
®
membrane with Arctangle
®
Loading Stations
™
(uniaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 1.5%
Maximum achievable % elongation with the Flex Jr.
™
: 7.9%
FlexFlow
™
(equibiaxial strain):
Minimum achievable % elongation with the Flex Jr.
™
: 0.8%
Maximum achievable % elongation with the Flex Jr.
™
: 4.3%
F
LEX
J
R
.
™
T
ENSION
P
HYSICAL
S
PECIFICATIONS
Flex Jr.
™
Laptop Computer:
Size, Open W x H x D:
15.0" x 10.25" x 10.25" (38.10 x 26.04 x 26.04 cm)
Size, Closed W x H x D: 15.0" x 1.2" x 10.25" (38.10 x 3.04 x 26.04 cm)
Power Requirements:
120/230 VAC, 50/60 Hz
Weight (unit only):
4.6 lbs. (2.09 kg)
Flex Jr.
™
Tension FlexLink
®
:
Size, W x H x D:
10.0” x 10.0” x 7.0” (25.40 x 25.40 x 17.78 cm)
Power Requirements:
115/230V – 6/3A – 60/50 Hz