Intervals and time limits
Measures
Every 2 years
Carry out a general inspection of the gear unit
Check the cooling coil
Check that all of the fastening bolts are tight
Clean the fan and gear unit
Every 20 000 operating hours, at least every
4 years
Change the oil if using semi-synthetic oil of API Group
III, PAO or PG oil (or depending on the result of the oil
sample test)
6 years after the specified date of manufacture Change the hoses
Further information
Further information about additional maintenance and servicing activities can be found in the
separate data sheet in the overall documentation for the gear unit.
Further information about installed components can be found in the operating instructions for
the components in the complete documentation for the gear unit.
8.3
Maintenance and service work
Introduction
You can find maintenance and servicing measures relating to gear unit lubrication and
preservation, which are not provided in this chapter, in BA 7300 in the complete gear unit
documentation.
8.3.1
Cleaning the fan and gear unit
Introduction
The gear unit can sustain damage due to inadequate cooling if you operate it with a damaged
or soiled fan. Depending on the conditions at the site of installation, it may therefore be
necessary to clean the fan and gear unit more frequently than stipulated in the maintenance
schedule.
Procedure
Proceed as follows to clean the fan and gear unit:
1. Remove the air guide cover.
2. Use a hard brush to remove any stubborn dirt from the impeller, air guide cover and
protective grille. Never use a high-pressure cleaning device.
3. Treat any areas of corrosion.
Maintenance
8.3 Maintenance and service work
REDUREX Gear unit 5200en
Operating Instructions 03/2019
93
Содержание K.A Series
Страница 2: ...07 03 2019 13 01 V4 00...
Страница 10: ...Table of contents REDUREX Gear unit 5200en 10 Operating Instructions 03 2019...
Страница 44: ...Description 3 16 Auxiliary drive REDUREX Gear unit 5200en 44 Operating Instructions 03 2019...
Страница 82: ...Mounting 5 9 Final work REDUREX Gear unit 5200en 82 Operating Instructions 03 2019...
Страница 104: ...Maintenance 8 4 Possible faults REDUREX Gear unit 5200en 104 Operating Instructions 03 2019...
Страница 106: ...Service Support REDUREX Gear unit 5200en 106 Operating Instructions 03 2019...
Страница 108: ...Disposal REDUREX Gear unit 5200en 108 Operating Instructions 03 2019...
Страница 110: ...Spare parts REDUREX Gear unit 5200en 110 Operating Instructions 03 2019...
Страница 112: ...Quality documents A 1 Declaration of incorporation REDUREX Gear unit 5200en 112 Operating Instructions 03 2019...
Страница 122: ...Technical data B 5 Enveloping surface sound pressure level REDUREX Gear unit 5200en 122 Operating Instructions 03 2019...
Страница 126: ...Index REDUREX Gear unit 5200en 126 Operating Instructions 03 2019...
Страница 127: ......