Observe the applicable instructions concerning fire and explosion protection of the battery
manufacturer.
Install a fuse of appropriate size in the positive connection of the starter battery. Install as close to
the battery as possible but with a max. distance of 300 mm (12 in) from the battery.
The cable from the battery to the fuse shall be protected with a conduit/protective sleeve against
fraying.
Use self-extinguishing and fire-protected cables for installation that are designed for max. temperatures of 90 °C,
195 °F.
Install the battery cables in such a way that the insulation cannot be removed by chafing or other mechanical
stresses.
The battery terminals must be protected against accidental short-circuiting.
Inside the Fischer Panda generator capsule, the positive battery cable must be routed so that it is protected from
heat and vibrations by means of an adequate conduit/protective sleeve. It must be installed so that it does not come
into contact with rotating parts or such that heat up during operation such as pulley, exhaust manifold, exhaust pipe,
and motor itself. Do not overtighten the cable, as it may be damaged otherwise.
After completing the installation, perform a test run of the generator and check the battery cable installation during
and after the test run. Implement corrections as necessary.
Fig. 1.6-1: Sample diagram for starter battery installation
1.6.4 General safety instructions for handling batteries
These instructions shall apply in addition to the instructions of the battery manufacturer:
• While you are working on the batteries, a second person should be within earshot to help you if
necessary.
• Keep water and soap ready in case battery acid is burning your skin.
• Wear eye protection and protective clothing. Do not touch your eyes while handling batteries.
Содержание 5000i PVK-U
Страница 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 30 10 12 Leere Seite Intentionally blank Basics...
Страница 48: ...The Panda Generator Seite Page 48 Kaptitel Chapter 4 The Panda Generator 30 10 12...
Страница 126: ...Generator Tables Seite Page 126 Kaptitel Chapter 8 Generator Tables 30 10 12...
Страница 146: ...Installation Page 146 Chapter 11 Installation 30 10 12 11 3 Dimensions Fig 11 3 0 1 Housing of the Panda iControl2 panel...
Страница 150: ...Page 150 Chapter 11 Installation 30 10 12 Intentionally left blank Installation...
Страница 152: ...Page 152 Chapter 12 Maintenance 30 10 12 Intentionally left blank Maintenance...
Страница 158: ...Page 158 Chapter 14 Annex 30 10 12 Intentionally left blank Annex...