Maintainence
Seite/Page 104 - Kaptitel/Chapter 7: Maintainence
30.10.12
Note:
The external fuel pump can be started manual by an option in
the iControl2 panel. See iControl2 manual for details.
Fig. 7.6-1: Ventilation screw at the fuel solenoid valve
Ventilation Screw
4.) Open the ventilation screw located at the fuel solenoid valve. The
„START“ button must continue to be pressed, whilst opening the screw. A
large cloth or Kleenex tissue must be laid beneath the connection to prevent
escaping fuel running into the capsule. If the fuel runs out without air
bubbles, then the ventilation screw can be closed. Only then may the
„START“ button be released.
5.) Switch the panel „OFF“.
This procedure must be repeated several times, until fuel
(nonporously) withdraws perfectly at the ventilation
screw.
Fig. 7.6-2: Injection nozzles
Injection nozzles
Pressing the starter button can now start the machine. The machine should
start after a short period.
If this does not occur, then a connecting nut fitted to the injection line must
be loosened and starting procedure repeated. Retighten the washers after
successfully starting. The injection line must be raised by several
millimetres.
Switch main switch "OFF"
7.6.2 Replacement of the fuel filter
Fig. 7.6.2-1: Fuel Filter
Exchanging the filter, depending upon fuel contamination,
should take place after 300 operational hours at the very
least. The inlet must be clamped, before exchanging the
filter.
Remove the hoses from the used filter and fasten them to the
new filter. The arrow on the filter housing indicates the
direction of the fuel flow. A clogged filter causes a decreased
power output of the generator.
10
17
Содержание 5000i PVK-U
Страница 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 30 10 12 Leere Seite Intentionally blank Basics...
Страница 48: ...The Panda Generator Seite Page 48 Kaptitel Chapter 4 The Panda Generator 30 10 12...
Страница 126: ...Generator Tables Seite Page 126 Kaptitel Chapter 8 Generator Tables 30 10 12...
Страница 146: ...Installation Page 146 Chapter 11 Installation 30 10 12 11 3 Dimensions Fig 11 3 0 1 Housing of the Panda iControl2 panel...
Страница 150: ...Page 150 Chapter 11 Installation 30 10 12 Intentionally left blank Installation...
Страница 152: ...Page 152 Chapter 12 Maintenance 30 10 12 Intentionally left blank Maintenance...
Страница 158: ...Page 158 Chapter 14 Annex 30 10 12 Intentionally left blank Annex...