![Fischer Panda 15 mini PMS Digital Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/fischer-panda/15-mini-pms-digital/15-mini-pms-digital_manual_2294276082.webp)
Maintenance Instructions
Seite/Page 82 - Kapitel/Chapter 7: Maintenance Instructions
12.8.20
If oil-level is still too low (under 2/3): repeat steps 4-6.
7.6.2 After the oil level check and refilling the oil
• Put the oil dipstick back into the check rail.
• Close the oil filling cap.
• Remove potential oil stains and splashes from the generator and surroundings.
• Close the generator casing.
• Remove lock against accidental generator start.
7.7 Replacement of engine oil and engine oil filter
You require:
- Engine oil. See attachment.
- New oil filter (not with generators with EA300
engines)
- Sealing for oil drain screw
- Personal protective gear
- Container to collect used oil (heat resistant and
of sufficient size)
- Open-ended wrench for oil drain screw
- Paper towels and cloth
- Oil filter wrench
- Oil resistant mat, so prevent used oil from
getting into underground water
The generator must be placed at level.
• with vehicular generators: Place the vehicle on a levelled surface.
• with PSC generators: Place the generator on a levelled surface.
• with marine generators: Change the oil when the ship is not lop-sided.
Run the generator for about 10 minutes to ensure that the engine is warm.
Wait for 3 minutes, so the oil can flow back into the oil pan.
Caution: Burn hazard!
Generator and coolant can be hot during and after
operating.
Wear personal protective equipment. (Gloves, protective
goggles, protective clothing and safety shoes)
1. Prepare generator.
- Assure generator against accidental start.
- Open the generator casing.
Содержание 15 mini PMS Digital