Generator control system
Based on VCS183
DS_VCS183
Page 34
Rev. 06
www.fischerpanda.com
©Fischer Panda generators Inc.
Advanced selections / data menu
The panel gives access to additional data as well as panel and VCS
settings and configurations from within the advanced selections
/data menu. To enter this menu the user needs to press and hold
down button S2, then press button S3, and finally release both
buttons at the same time.
Whenever the generator is running there is no access to altering
any settings, neither the ones stored in the VCS nor panel
settings. In such case, selecting advanced selections / data menu
will transition immediately into the
“View more data” menu; see
Figure 17: Selection View more data
With the generator not running the advanced selections menu
will be displayed.
Navigating through advanced selection menus and sub-menus
Throughout advanced selection menu as well as in all sub-menus
navigation between menus will always follow the below pattern:
•
Selection bar may be moved by clicking S3,as is indicated
in bottom line (“S3: next”)
•
Currently highlighted item may be selected by clicking S4,
as indicated in bottom line (“S4: select”)
•
Selecting “Return to normal” will always jump back into
basic display mode, page 1
Structure of sub-menus is depicted in
Figure 15: Advanced menu, page 2
and
Figure 16: Advanced menu, page 3
below:
View more data
Top line of this menu will always show actual operational status, bottom line is again reserved for
faults/message display while remaining 3 lines are used to cycle through additional display data listed
below. Cycling time again is approx. 0.7 sec., cycling process may be halted/re-started by clicking S4. To
exit this menu the user needs to click S3.
Data available in menu “View more data”
1.
Frequency as sensed by the CT board
2.
Temperature CT186, main CPU control board
3.
Temperature terminals of CT186
4.
Temperature on VCS183 control board
5.
Temperature inside control panel
6.
Actuator voltage
7.
Actuator current
Figure 14: Advanced menu, page 1
Figure 15: Advanced menu, page 2
Figure 16: Advanced menu, page 3
Figure 17: Selection View more data