![Fischer Panda 15 mini PMS Digital Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/fischer-panda/15-mini-pms-digital/15-mini-pms-digital_manual_2294276073.webp)
Installation Instructions
12.8.20
Kapitel/Chapter 6: Installation Instructions - Seite/Page 73
Fig. 6.11.2-1: AC-Control box
represantive picture
1 Grounding point at the AC-Control box
2 Label for mounting direction at the AC-Control box
The AC-Control box is necessary for the operation of Panda generators. According to the generator capacity the AC
Control box is variable dimensioned and equipped. It is supplied with a lockable cap.
This cap must necessarily be locked when the generator is running, as at all models during operation, 400 V is may
present in the AC control box.
Mount the AC-Control box at a siutable wall next to the generator. Respect the mounting direction mentioned on the
AC-Control box . Install the electrical connection regarding your wiring diagram.
Danger to life - 400 V AC
Only qualified personnel may carry out working at the
AC-Control box.
The AC-Control box must be grounded
Fig. 6.11-2:
AC-Control box - example
2
1
3
2
1
1. Additional electronic
2. Electric connection terminal
3. Capacitors
Содержание 15 mini PMS Digital
Страница 8: ...Seite Page 8 Kapitel Chapter 1 12 8 20 Leere Seite Intentionally blank...
Страница 46: ...Seite Page 46 Kapitel Chapter 4 The Panda Generator 12 8 20 Leere Seite Intentionally blank The Panda Generator...
Страница 116: ...Seite Page 116 Kapitel Chapter 8 Generator Faults 12 8 20 Leere Seite Intentionally blank Generator Faults...