Proprietary and Confidential
Sequence of operation
26
Checking flame signal in auto
LED STATE
It is possible to check the flame signal in AUTO.
The procedure is the same as outlined for placing
the BurnerPRO into check mode during PTFI
(press and hold the reset button until the status
LED changes from green to amber). The fan LED
will blink to indicate that the LEDs are showing
flame signal.
The flame signal will be indicated by the middle
five LEDs to indicate the flame signal in
increments of 20%.
To exit flame signal mode, simply press the reset
button one time.
BLINK
20%
40%
60%
80%
100%