REMOVInG ThE DEVIcE

Removing (Exclusion)

 - Z-Wave device learning mode, allowing to 

remove the device from existing Z-Wave network.
Removing the device restores all the default parameters of the de-

vice, but does not reset power metering data.

#4: Removing the device

NOTE

In case of problems 

with removing using 

the S1 switch, use 

B-button instead (lo-

cated on the housing).

i

To remove the device from the Z-Wave network:
1.  Make sure the device is powered.
2.  Identify the S1 switch.
3.  Set the main controller in remove mode (see the controller’s 

manual).

4.  Quickly, triple click the S1 switch.
5.  Wait for the removing process to end.
6.  Successful removing will be confirmed by the Z-Wave controller’s 

message.

NOTE

If parameter 40 ena-

bles scenes for triple 

S1 click, disable it or 

use B-button instead 

to remove the device.

i

NOTE

If parameter 24 is set 

to 1, use S2 switch in-

stead to remove the 

device.

i

Содержание FGR-223

Страница 1: ...er blinds 13 7 Operating gate motors 14 8 Menu 15 9 Resetting to factory defaults 16 10 Power and energy consumption 17 11 Associations 18 12 Z Wave range test 19 13 Activating scenes 20 14 Z Wave specification 21 15 Advanced parameters 24 16 Specifications 32 17 Regulations 33 O P E R A T I N G M A N U A L EN FIBARO ROLLER SHUTTER 3 FGR 223 v1 0 ...

Страница 2: ...lectrical home installation Faulty connection or use may result in fire or elec tric shock All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Even when the device is turned off voltage may be present at its ter minals Any maintenance introducing changes into the configuration of connections or the load must be always performed with di...

Страница 3: ...and other single phase AC powered devices Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas The device is equipped with power and energy monitoring It allows to control connected devices either via the Z Wave network or via a switch connected directly to it 1 Description and features FIBARO Roller Shutter 3 is a fully compatible Z Wave PLUS device NOTE The dev...

Страница 4: ... roller blind motors with electronic or mechanical limit switches only Notes for the diagrams S1 terminal for 1st switch used to add remove the device S2 terminal for 2nd switch Q2 2nd output terminal for shutter motor Q1 1st output terminal for shutter motor L terminal for live lead N terminal for neutral lead B service button used to add remove the de vice and navigate the menu Roller Shutter 3 ...

Страница 5: ...en the wall switch box 3 Connect with the following the diagram Wiring diagram standard blinds 4 Verify if the device is connected correctly 5 Arrange the device and its antenna in a wall switch box 6 Close the wall switch box 7 Switch on the mains voltage Roller Shutter 3 L N S1 S2 L N M N Q2 B Q1 PE ...

Страница 6: ...n the wall switch box 3 Connect with the following the diagram Wiring diagram blinds with built in driver 4 Verify if the device is connected correctly 5 Arrange the device and its antenna in a wall switch box 6 Close the wall switch box 7 Switch on the mains voltage Roller Shutter 3 L N S1 S2 L N M N Q2 B Q1 L PE ...

Страница 7: ...d to connect an emergency stop button to the motors neutral N wire In emergency pushing the emergency stop button will cut the power and stop the gate L N M N safety switch NC sensor NC Roller Shutter 3 B limit switches L N S1 S2 Q2 Q1 PE Wiring diagram gate motors 1 Switch off the mains voltage disable the fuse 2 Open the installation box 3 Connect with the following the diagram 4 Verify if the d...

Страница 8: ...ler s message NOTE In case of problems with adding using the S1 switch use B but ton instead located on the housing i NOTE SmartStart ena bled products can be added to SmartStart enabled Z Wave con troller by scanning the Z Wave QR Code present on the prod uct SmartStart prod uct will be added automatically within 10 minutes of being switched on in the network range i To add the device to the Z Wa...

Страница 9: ...o cated on the housing i To remove the device from the Z Wave network 1 Make sure the device is powered 2 Identify the S1 switch 3 Set the main controller in remove mode see the controller s manual 4 Quickly triple click the S1 switch 5 Wait for the removing process to end 6 Successful removing will be confirmed by the Z Wave controller s message NOTE If parameter 40 ena bles scenes for triple S1 ...

Страница 10: ...for at least 3 seconds 3 Press and hold the same switch again for at least 3 seconds 4 Press and hold the same switch again for at least 3 seconds 5 The device will perform the calibration process completing full cycle up down and up again 6 Test whether the positioning works correctly Standard roller blind positioning Calibration using the B button 1 Make sure the device is supplied the device ad...

Страница 11: ...ake sure the device is supplied momentary switch is connected to S1 and S2 terminals the device added to the Z Wave network parameter 151 is set to 2 blinds are calibrated 2 By default time of transition between extreme positions is set to 150 1 5 seconds in parameter 152 3 Turn slats between extreme positions by holding or switch If after full cycle a blind starts moving up or down de crease valu...

Страница 12: ...rameters 155 and 156 3 Move roller blinds between extreme positions by clicking or switch If roller blind stops before reaching top increase value of parameter 155 If roller blind does not stop after reaching top decrease value of parameter 155 If roller blind stops before reaching bottom increase val ue of parameter 156 If roller blind does not stop after reaching bottom de crease value of parame...

Страница 13: ...ible for managing the blind s movement Description switch connected to the S1 terminal switch connected to the S2 terminal Click switch initiate up movement Click switch initiate down movement If the blind is moving clicking any button will stop the move ment Operating slats of venetian blinds When operating venetian blinds it is possible to manage angle of the slats Hold switch initiate slats rot...

Страница 14: ...l It is recommended to connect an IR barrier an emergency stop but ton or any alarm mechanism to S2 terminal Opening a contact in a device connected to S2 terminal will always result in stopping a mo tor in current position Using momentary switch Click S1 switch move gate in sequence OPEN STOP CLOSE STOP OPEN Open S2 contact stop movement Automatic closing After full opening the gate will automati...

Страница 15: ...device from the wall switch box 3 Switch on the mains voltage 4 Press and hold the B button to enter the menu 5 Wait for the LED to indicate the desired menu position with colour WHITE start calibration GREEN reset energy consumption memory VIOLET start range test YELLOW reset the device 6 Quickly release and click the B button again 8 Menu ...

Страница 16: ...ge 4 Press and hold the B button to enter the menu 5 Wait for the LED indicator to glow yellow 6 Quickly release and click the B button again 7 After few seconds the device will be restarted which is signalled with the red LED indicator colour NOTE Resetting the device is not the recommend ed way of removing the device from the Z Wave network Use reset procedure only if the primary con troller is ...

Страница 17: ... power consumed over period of one hour 1kWh 1000Wh CAUTION The device stores pe riodically every hour the consumption data in the device mem ory Disconnecting the module from the power supply will not erase stored energy consumption data Resetting consumption memory The device allows to erase stored consumption data in three ways a Using functionality of a Z Wave controller see the controller s m...

Страница 18: ...Roller Shutter or scene may be controlled only through a Z Wave controller The device in 2nd and 3rd group allows to control 5 regular or mul tichannel devices per an association group with the exception of LifeLine that is reserved solely for the controller and hence only 1 node can be assigned To add an association using the Home Center controller 1 Go to the device options by clicking the icon ...

Страница 19: ...icates with the main controller directly Visual indicator pulsing yellow the device tries to establish a rout ed communication with the main controller through other modules repeaters Visual indicator glowing yellow the device communicates with the main controller through the other modules After 2 seconds the device will retry to establish a direct communication with the main controller which will...

Страница 20: ...itch Action Scene ID Attribute Switch connected to S1 terminal Switch clicked once 1 Key Pressed 1 time Switch clicked twice 1 Key Pressed 2 times Switch clicked thrice 1 Key Pressed 3 times Switch held 1 Key Held Down Switch released 1 Key Released Switch connected to S2 terminal Switch clicked once 2 Key Pressed 1 time Switch clicked twice 2 Key Pressed 2 times Switch clicked thrice 2 Key Presse...

Страница 21: ...FICATION 0x71 V8 YES PROTECTION 0x75 V2 YES MULTI_CHANNEL 0x60 V4 YES CENTRAL_SCENE 0x5B V3 YES FIRMWARE_UPDATE_MD 0x7A V4 YES APPLICATION_STATUS 0x22 V1 BASIC 0x20 V1 YES 14 Z Wave specification Endpoint 1 Generic Device Class GENERIC_TYPE_SWITCH_MULTILEVEL Specific Device Class SPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL Description represents switch connected to the S1 terminal Endpoint 2 Generic Devic...

Страница 22: ... 1 ZWAVEPLUS_INFO 0x5E V2 SWITCH_MULTILEVEL 0x26 V4 YES ASSOCIATION 0x85 V2 YES MULTI_CHANNEL_ASSOCIATION 0x8E V3 YES ASSOCIATION_GRP_INFO 0x59 V2 YES SECURITY 0x98 V1 SECURITY_2 0x9F V1 SUPERVISION 0x6C V1 METER 0x32 V3 YES NOTIFICATION 0x71 V8 YES APPLICATION_STATUS 0x22 V1 Endpoint 2 ZWAVEPLUS_INFO 0x5E V2 SWITCH_MULTILEVEL 0x26 V4 YES ASSOCIATION 0x85 V2 YES MULTI_CHANNEL_ASSOCIATION 0x8E V3 Y...

Страница 23: ...sible S1 and S2 cannot change relay state any other functionality is available menu RF remote 0 Unprotected The device accepts and respond to all RF Commands RF remote 1 No RF control command class Basic and Switch Binary are rejected every other command class will be handled Meter Command Class Same for Root Endpoint 1 and Endpoint 2 Meter Type Scale Rate Type Precision Size Electric 0x01 Electri...

Страница 24: ...e settings 0 momentary switches 1 toggle switches 2 single momentary switch the switch should be connected to S1 terminal Default setting 2 Parameter size 1 byte 24 Inputs orientation This parameter allows reversing the operation of switches connected to S1 and S2 without changing the wiring Available settings 0 default S1 1st channel S2 2nd channel 1 reversed S1 2nd channel S2 1st channel Default...

Страница 25: ...er This parameter determines to which alarm frames and how the device should react The parameters consist of 4 bytes three most significant bytes are set according to the official Z Wave protocol specification Available settings 1B MSB Notification Type 2B Notification Status 3B Event State Parameters 4B LSB action 0 no action 1 open blinds 2 close blinds Default setting 0x05 0xFF 0x00 0x00 Water ...

Страница 26: ...ds 2 close blinds Default setting 0x01 0xFF 0x00 0x00 Smoke Alarm any notification no action Parameter size 4 bytes 33 Alarm configuration 4th slot CO This parameter determines to which alarm frames and how the device should react The parameters consist of 4 bytes three most significant bytes are set according to the official Z Wave protocol specification Available settings 1B MSB Notification Typ...

Страница 27: ...tion Parameter size 4 bytes NOTE Parameter 41 values may be combined e g 1 2 3 means that scenes for single and double click are sent i 40 S1 switch scenes sent This parameter determines which actions result in sending scene IDs assigned to them Available settings 1 Key pressed 1 time 2 Key pressed 2 times 4 Key pressed 3 times 8 Key hold down and key released Default setting 0 Parameter size 1 by...

Страница 28: ...r determines in what time intervals the periodic power reports are sent to the main controller Periodic reports do not de pend on power change parameter 61 Available settings 0 periodic reports are disabled 30 32400 30 32400s report interval Default setting 3600 1h Parameter size 2 bytes 65 Energy reports on change This parameter determines the minimum change in consumed ener gy that will result i...

Страница 29: ... 2 Venetian blind with positioning 3 gate without positioning 4 gate with positioning 5 roller blind with built in driver 6 roller blind with built in driver impulse Default setting 1 Parameter size 1 byte 152 Venetian blind time of full turn of the slats For Venetian blinds parameter 151 set to 2 the parameter deter mines time of full turn cycle of the slats For gates parameter 151 set to 3 or 4 ...

Страница 30: ...ermines the time after which the motor will be stopped after end switch con tacts are closed For gates parameter 151 set to 3 or 4 the parameter determines time after which the gate will start closing automatically if S2 contacts are opened if set to 0 gate will not close Available settings 0 600 0 60s time Default setting 10 1s Parameter size 2 bytes 155 Motor operation detection Power threshold ...

Страница 31: ...s time needed for roller blinds to reach the bottom For modes with positioning value is set automatically during calibra tion otherwise it must be set manually Available settings 1 90000 0 01 900 00s every 0 01s move ment time Default setting 6000 60s Parameter size 4 bytes ...

Страница 32: ...ower factor inductive loads single phase AC motors electronic or mechanic up to 0 8W 0 35 C 10 95 RH without condensation micro gap relay switch μ Ø 50mm depth 60mm Z Wave 500 series chip EIRP up to 6dBm 868 4 or 869 8 MHz EU 908 4 or 916 0 MHz US 921 4 or 919 8 MHz ANZ 869 0 MHz RU up to 50m outdoors up to 40m indoors depending on terrain and building structure 42 5 x 38 25 x 20 3 mm RoHS 2011 65...

Страница 33: ...fferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes and modifications not expressly approved by the manufactu rer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules Industry Canada IC Compliance Notice This device complies with Industry Canada li...

Страница 34: ...er exists 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用 者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現 有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性 電機設備之干擾 Declaration of conformity Hereby Fibar Group S A declares that the device is in com pliance with the essential requirements and other relevant provisions of Directive 2014 53 EU The full text of the EU d...

Отзывы: