12
POSITIOnInG cAlIBRATIOn
Roller blind with built-in driver positioning
1. Make sure:
• the device is supplied,
• momentary switch is connected to S1 and S2 terminals,
• the device added to the Z-Wave network,
• parameter 151 is set to 5 or 6.
2. By default, time of transition between extreme positions is
set to 600 (6 seconds) in parameters 155 and 156.
3. Move roller blinds between extreme positions by clicking
or switch:
• If roller blind stops before reaching top - increase value
of parameter 155,
• If roller blind does not stop after reaching top - decrease
value of parameter 155,
• If roller blind stops before reaching bottom - increase val-
ue of parameter 156,
• If roller blind does not stop after reaching bottom - de-
crease value of parameter 156,
4. Repeat previous step until satisfactory positioning is
achieved.
5. Test whether the positioning works correctly.