25
ADVAncED PARAMETERS
30. Alarm configuration - 1st slot
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most significant
bytes are set according to the official Z-Wave protocol specification.
Available settings:
1B
[MSB] - notification Type
2B
- notification Status
3B
- Event/State Parameters
4B
[lSB] - action:
0
- no action
1
- open blinds
2
- close blinds
Default setting:
[0x00, 0x00, 0x00, 0x00]
(disabled)
Parameter size:
4
[bytes]
31. Alarm configuration - 2nd slot (Water)
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most significant
bytes are set according to the official Z-Wave protocol specification.
Available settings:
1B
[MSB] - notification Type
2B
- notification Status
3B
- Event/State Parameters
4B
[lSB] - action:
0
- no action
1
- open blinds
2
- close blinds
Default setting:
[0x05, 0xFF, 0x00, 0x00]
(Water Alarm, any notification, no action)
Parameter size:
4
[bytes]
ALARM CONFIGURATION
NOTE
Alarm with lower
number has the high-
er priority, thus first
alarm will override
other alarms with the
same type.
i
NOTE
Setting notification
Value to 0xFF will re-
sult in launching the
action twice: when
alarm occurs and is
cancelled.
i