22
Z-WAVE SPEcIFIcATIOn
Notification Command Class:
The device uses notification command class to report different events
to the controller (“lifeline” group).
notification
Type
Event
Event Parameters
Power
Management
[0x08]
Over-current detected
[0x06]
System
[0x09]
System hardware Failure
[0x03]
Device overheat
[0x01]
command class
Version
Secure
Endpoint 1
ZWAVEPluS_InFO [0x5E]
V2
SWITch_MulTIlEVEl [0x26]
V4
yES
ASSOcIATIOn [0x85]
V2
yES
MulTI_chAnnEl_ASSOcIATIOn [0x8E]
V3
yES
ASSOcIATIOn_GRP_InFO [0x59]
V2
yES
SEcuRITy [0x98]
V1
SEcuRITy_2 [0x9F]
V1
SuPERVISIOn [0x6c]
V1
METER [0x32]
V3
yES
nOTIFIcATIOn [0x71]
V8
yES
APPlIcATIOn_STATuS [0x22]
V1
Endpoint 2
ZWAVEPluS_InFO [0x5E]
V2
SWITch_MulTIlEVEl [0x26]
V4
yES
ASSOcIATIOn [0x85]
V2
yES
MulTI_chAnnEl_ASSOcIATIOn [0x8E]
V3
yES
ASSOcIATIOn_GRP_InFO [0x59]
V2
yES
SEcuRITy [0x98]
V1
SEcuRITy_2 [0x9F]
V1
SuPERVISIOn [0x6c]
V1
APPlIcATIOn_STATuS [0x22]
V1
Multichannel Command Class: