7
InSTAllATIOn
Installation with gate motors
:
• Installation of the gate driver may be performed only by certified
professionals.
• The motor must be equipped with the appropriate limit switches.
• It is recommended to connect a nc (normally closed) contact of
an IR barrier to S2 terminal. Opening the contact will stop the gate.
• In addition, it is recommended to connect an emergency stop
button to the motors neutral (n) wire. In emergency, pushing the
emergency stop button will cut the power and stop the gate.
L
N
M
N
safety switch
NC
sensor
NC
Roller
Shutter 3
B
limit
switches
L
N
S1 S2 Q2
Q1
PE
Wiring diagram - gate motors
1. Switch off the mains voltage (disable the fuse).
2. Open the installation box.
3. connect with the following the diagram:
4. Verify if the device is connected correctly.
5. Arrange the device and its antenna in the installation box.
6. close the installation box.
7. Switch on the mains voltage.