ADVAncED PARAMETERS
153. Set slats back to previous position
For Venetian blinds (parameter 151 set to 2) the parameter determines
slats positioning in various situations.
The parameter is irrelevant for other modes.
Available settings:
0
– slats return to previously set position only in
case of the main controller operation.
1
– slats return to previously set position in case
of the main controller operation, momentary
switch operation, or when the limit switch is
reached.
2
– slats return to previously set position in
case of the main controller operation, momen-
tary switch operation, when the limit switch is
reached or after receiving the Switch Multilevel
Stop control frame
Default setting:
1
Parameter size:
1
[byte]
154. Delay motor stop after reaching end switch
For blinds (parameter 151 set to 1, 2, 5 or 6) the parameter determines
the time after which the motor will be stopped after end switch con-
tacts are closed.
For gates (parameter 151 set to 3 or 4) the parameter determines time
after which the gate will start closing automatically if S2 contacts are
opened (if set to 0, gate will not close).
Available settings:
0-600
(0 - 60s) - time
Default setting:
10
(1s)
Parameter size:
2
[bytes]
155. Motor operation detection
Power threshold to be interpreted as reaching a limit switch.
Available settings:
0
- reaching a limit switch will not be detected
1-255
(1-255W) - report interval
Default setting:
10
(10W)
Parameter size:
2
[bytes]
156. Time of up movement
This parameter determines the time needed for roller blinds to reach
the top.
For modes with positioning value is set automatically during calibra-
tion, otherwise it must be set manually.
Available settings:
1-90000
(0.01 - 900.00s, every 0.01s) - move-
ment time
Default setting:
6000
(60s)
Parameter size:
4
[bytes]
NOTE
If parameter 20 is set
to 1 (toggle switch),
change value of pa-
rameter 153 to 0 for
slats to work properly.
i