Functions
25
5.2.2.4
Input word Em.2 pressure P2
In the input word Em.0, the pressure value P2 is displayed in accordance with the parameterised
pressure unit. The presetting of the module parameter “Unit pressure” is “mbar”.
Data format of input word sign + 15 bits, right-justified
D15
D14
D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
VZ
B14
B13 B12 B11 B10 B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Abbreviations used
VZ
Sign, for data format sign + 15 bit, always=0, positive value
B0 … B14
Pressure value P2
DO … D15
16-bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 8: Data format of input word Em.2 "Pressure P2"
Pressure P2
Input value
[bar]
[kPa]
[mbar]
[psi/10]
0
0
0
0
1
100
1000
145
4
400
4000
580
…
…
…
…
7.36
736
7360
1067
…
…
…
…
14
1400
14000
2030
Tab. 9: Unit-dependent pressure values
The pressure measurement data is presented according to the unit and is rounded off.
Measured value resolution:
• kPa: 2
• mbar: 20
• psi/10: 5
5.2.2.5
Input word Em.5 pressure change DP2
The pressure change value is transmitted exclusively as a selectable input word, Em.5. The output
word, Am.1, input address must in this case have the value 0. The pressure change value is specified
in the data format sign + 15 bits.
Depending on the parameterised pressure unit and the parameterised measurement interval, the
pressure change is sent to the higher-order controller as the input word, 2 bytes, 16 bits. The pressure
change value is stored in the input word as follows.