24
Festo — MSE6-E2M — 2022-08d
Functions
Data format of input word Sign + 15 bits, right-justified
Abbreviations used
VZ
Sign, for data format sign + 15 bits always = 0, i.e. positive value
B0 … B14
Flow rate value
D0 … D15
16-bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 5: Data format of input word Em.0 flow rate
Flow rate
Input value
[l/min]
[l/min]
[scfm/10]
0
0
0
50
50
18
…
…
…
5000
5000
1766
Tab. 6: Unit-dependent flow rate values
5.2.2.3
Input word Em.1 consumption
In the input word Em.1, the consumption value V0, 16 bits, is displayed in accordance with the
parameterised consumption unit and flow rate standard and limited to max. 65535, 16-bit value,
independently of the parameterised unit.
The default value of the unit consumption module parameter is l, the default value of the unit flow
rate standard module parameter is DIN 1343. If there is a change to the flow rate unit and/or flow rate
standard, the consumption is reset to the value 0. If there is a change to the consumption unit, the
consumption value remains unchanged and is converted correspondingly.
Data format of input word 16 bits, right-justified
D15
D14
D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
B15
B14
B13 B12 B11 B10 B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Abbreviations used
B0 … B15
Consumption value
D0 … D15
16-bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 7: Data format of input word Em.1 "Consumption"
Содержание MSE6-E2M
Страница 1: ...MSE6 E2M Energy efficiency module Operating instruc tion 8163321 2022 08d 8163323...
Страница 83: ......