4. Commissioning
4−27
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
4. Step: Record is running
After the record start with SPOS.ACK = 1 has been detected,
CPOS.START can be reset.
Control bytes (step 4)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
RESET
BRAKE
STOP
ENABLE
Byte 1
0
0
0
0
0
1/0
1
1
CPOS
CLEAR
TEACH
JOGN
JOGP
HOM
START
HOLD
Byte 2
0
0
0
0
0
0
0
0
Record no.
Record number of the next record to be started. Any
Byte 3
x
x
x
x
x
x
x
x
res.
Byte 4 ... 8: reserved (= 0)
The running record is signalled with SPOS.MC = 0.
Resetting CPOS.START is signalled back with SPOS.ACK = 0.
Status bytes (step 4)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI
24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
0
0
0
1
0
0
1
1
SPOS
REF
STILL
DEV
MOV
TEACH
MC
ACK
HOLD
Byte 2
1
x
x
x
x
x
0
0
Record no.
Acknowledgement of last started record: 36
Byte 3
0
0
1
0
0
1
0
0
RSB
XLIM
VLIM
RCE
COM1
RCC
RC1
Byte 4
x
x
x
x
x
x
x
x
Primary
actual
value
Byte 5 ... 8: Acknowledgement of the actual value of the position or force in the configured
system of units.
Содержание CPX-CMAX-C1-1
Страница 2: ......
Страница 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Страница 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Страница 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Страница 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Страница 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Страница 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Страница 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...