4. Commissioning
4−37
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
4.5.6
Acknowledge error
1. Step: Error message
Allocation of the control bytes (step 1)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
RESET
BRAKE
STOP
ENABLE
Byte 1
x
x
x
0
0
1/0
x
x
...
Byte 2 ... 8: Depending on the operating mode
Allocation of the status bytes (step 1)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI 24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
x
x
x
x
1
x
0
x
...
Byte 2 ... 8: Depending on the operating mode
Error message is displayed with SCON.FAULT = 1.
2. Step: Reset error messages
Allocation of the control bytes (step 2)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
RESET
BRAKE
STOP
ENABLE
Byte 1
x
x
x
0
1
1/0
x
x
...
Byte 2 ... 8: Depending on the operating mode
Allocation of the status bytes (step 2)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI 24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
x
x
x
x
0/1
x
x
x
...
Byte 2 ... 8: Depending on the operating mode
It could happen that a new malfunction occurs during
acknowledgement: Repeat step 2 (3x, then error handling).
Содержание CPX-CMAX-C1-1
Страница 2: ......
Страница 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Страница 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Страница 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Страница 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Страница 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Страница 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Страница 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...