3. Electrical installation
3−11
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
3.3
Ensuring protection class IP65
With a completely installed axis string (all plug connectors
inserted), the CMAX in the CPX terminal complies with protec
tion class IP65.
Note
To comply with protection class IP65:
·
Seal unused connections with the corresponding protec
tive caps.
If the axis interface is not used, then seal this using a FLANGE
RECEPTACLE, S712 protective cap. You will then comply with
protection class IP65.
For the VPWP, a protective cap of type ISK−M8 for the output
(DO, brake) is included in the scope of delivery.
Содержание CPX-CMAX-C1-1
Страница 2: ......
Страница 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Страница 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Страница 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Страница 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Страница 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Страница 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Страница 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...