4. Commissioning
4−36
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5. Step: Job completed
As soon as SPOS.ACK = 0, another setpoint value can be
specified or another job started. SPOS.MC remains 0 until the
last job has been completed.
Allocation of the control bytes (step 5)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
CCON
OPM2
OPM1
LOCK
RESET
BRAKE
STOP
ENABLE
Byte 1
0
1
0
0
0
1/0
1
1
CPOS
CLEAR
TEACH
JOGN
JOGP
HOM
START
HOLD
Byte 2
0
0
0
0
0
0
0
0
CDIR
FAST
XLIM
VLIM
CONT
COM2
COM1
ABS
Byte 3
0
x (1)
x
x
x (0)
x (0)
x (0)
x (0)
Secondary
setpoint
Byte 4: Setpoint value of the speed: in percentage of the specified value Speed in direct
mode" (PNU540): not relevant
Primary
setpoint
Byte 5 ... 8: Setpoint value of the position in the configured system of units (metric/lin
ear): not relevant
The end of the job is signalled back with SPOS.MC = 1.
Allocation of the status bytes (step 5)
Bit
B7
B6
B5
B4
B3
B2
B1
B0
SCON
OPM2
OPM1
FCT_MMI
24VL
FAULT
WARN
OPEN
ENABLED
Byte 1
0
1
0
1
0
0
1
1
SPOS
REF
STILL
DEV
MOV
TEACH
MC
ACK
HOLD
Byte 2
1
x
x
x
x
1
0
0
SDIR
FAST
XLIM
VLIM
CONT
COM2
COM1
ABS
Byte 3
x
1
x
x
0
0
0
0
Secondary
actual
value
Byte 4: Acknowledgement of the actual value of the speed in percentage of the set value
Speed in direct mode" (PNU540).
Primary
actual
value
Byte 5 ... 8: Acknowledgement of the actual value of the position or force in the
configured system of units.
Содержание CPX-CMAX-C1-1
Страница 2: ......
Страница 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Страница 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Страница 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Страница 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Страница 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Страница 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Страница 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...