5. Diagnostics and error handling
5−33
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.3.4
LEDs on the sensor interface
LEDs on the CASM−S−D2−R3
LED S1
LED S2
Status
CMAX error:
Green
Off
Ready for operation without errors.
Green
Red
Initialising via CAN completed.
Flashes green
Red
24 V present.
Off
Off
24 V not available.
E80
Green
Flashes red
once
Error: Sensor error (supply voltage < 12 V for longer than
15 ms).
E82
Green
Flashes red
twice
Error: Sensor error (cable break in sensor cable or elec
trical end position reached).
E87
Green
Flashes red
3 times
Error: Supply voltage (< 17 V for longer than 15ms).
E85
Green
Flashes red
4 times
Error: Communication error (Bus Off" status).
E80
LEDs on the CASM−S−D3−R7
LED S1
LED S2
Status
CMAX error:
Green
Off
Ready for operation without errors.
Green
Red
Initialising via CAN completed.
Flashes green
Red
24 V present.
Flashes green
Off
Not yet referenced.
(E10)
Off
Off
24 V unavailable.
E80
Green
Flashes red
once
Error: Sensor error.
E82
Green
Flashes red
twice
Error: Sensor cable (cable break in the sensor cable).
E87
Green
Flashes red
3 times
Error: Supply voltage (< 17 V for longer than 15ms).
E85
Green
Flashes red
4 times
Error: Communication error (Bus Off" status).
E80
Содержание CPX-CMAX-C1-1
Страница 2: ......
Страница 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Страница 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Страница 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Страница 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Страница 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Страница 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Страница 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Страница 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...