Ascertaining the number of bits for the process
data channel per CP system
Last used string
of CP system
ID
code
Process data
channel bits
Reserved address range
0
1
2
3
3
3
3
3
16
32
48
64
16 inputs/outputs
32 inputs/outputs
48 inputs/outputs
64 inputs/outputs
Example –
Calculating the physical addresses
1st. CP system 2nd. CP system 3rd. CP system
4th. CP system
Process data
channel bits
(assigned
strings)
16
(1)
48
(3)
64
(4)
32
(2)
Physical
word address
BA
BA + 16
BA + 16 + 48
BA + 16 + 48 + 64
BA = Basic address