LEDs
LED designation
Meaning
RC
Remote bus check
Lights up when connection is
made to the master
BA
Bus active
Lights up during data transfer
RD
Remote bus disable
Lighs up when data transfer
on the bus is interrupted or
when interface "REMOTE OUT"
is switched off.
POWER
Operating voltage display of
internal electronics
Lights up when operating
voltage is applied to pin 1 and
the node is ready to operate.
POWER V
Operating voltage display of
valves
Lights up when operating
voltage is OK (pin 2)
0..3
CP string LED
In starting phase:
blinks if the string assignment
has been modified since last
operation.
During operation:
lights up if a CP connection
is interrupted.
3.1.2 Normal operating status
In normal operating status the following LEDs on CP
node 6 light up:
( = lights up; = LED flashes; = out)
LEDs
Operating status
Error treatment
RC
BA
RD
POWER
POWER V
0...3 ERROR
normal
none
3. Diagnosis
3-4
CP FB6-E 9809c