A
Diagnostic messages
94
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
09-9
73A6
h
Angle encoder's
EEPROM too
small
It is not possible to save
all the data in the
EEPROM of the angle
encoder.
•
Reduce the number of
data records to be
saved. Please read
the documentation or
contact Technical Sup-
port.
Config-
urable
10-0
–
Overspeed (spin
protection)
–
Motor racing (“spin-
ning”) because the
commutation angle
offset is incorrect.
–
Motor is parametrised
correctly but the limit
for spinning protec-
tion is set too low.
•
Check the commuta-
tion angle offset.
•
Check the limit value
setting in the para-
meters.
Config-
urable
11-7
–
Homing: error in
encoder differ-
ence monitoring
Deviation between the
actual position value and
commutation position is
too great. External angle
encoder not connected or
faulty?
•
Deviation fluctuates,
e.g. due to gear back-
lash; cut-off threshold
may need to be in-
creased.
•
Check connection of
the actual value en-
coder.
Config-
urable
11-0
8A80
h
Error when hom-
ing is started
Controller enable missing.
Homing can only be star-
ted when closed-loop
controller enable is act-
ive.
•
Check the condition or
sequence.
Config-
urable
11-1
8A81
h
Error during hom-
ing
Homing was interrupted,
e.g. by:
–
Withdrawal of control-
ler enable.
–
Reference switch is
beyond the limit
switch.
–
External stop signal (a
phase was aborted
during homing).
•
Check homing se-
quence.
•
Check arrangement of
the switches.
•
If applicable, lock the
stop input during
homing if it is not de-
sired.
Config-
urable
Содержание CMMP-AS-***-M3 Series