6
Functions
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
39
Start(DIN)
2
1
HA
MC
Speed
<>
0
ERR
3
4
5
Error
HA: HOMING_ACTIVE
MC: MOTION COMPLETE
ERR: Error
1
0 … 10 ms
2
20 ms
3
Dependent on braking ramp
4
50 ms + x (x=delay until brake locked)
5
0 … 10 ms
Fig. 6.3