A
Diagnostic messages
114
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
42-9
–
Error when start-
ing the position-
ing task
–
Acceleration limit
value exceeded
–
Position record
blocked.
•
Check parametrisa-
tion and sequence
control, correct if ne-
cessary.
Config-
urable
42-0
8680
h
Positioning: no
follow-up posi-
tioning: stop
The positioning target
cannot be reached
through the positioning
or edge condition op-
tions.
•
Check parametrisa-
tion of the position re-
cords in question.
Config-
urable
42-1
8681
h
Positioning: re-
versing direction
of rotation not al-
lowed: stop
The positioning target
cannot be reached
through the positioning
or edge condition op-
tions.
•
Check parametrisa-
tion of the position re-
cords in question.
Config-
urable
42-2
8682
h
Positioning: re-
versing after halt
not allowed
The positioning target
cannot be reached
through the positioning
or edge condition op-
tions.
•
Check parametrisa-
tion of the position re-
cords in question.
Config-
urable
43-0
8081
h
Limit switch: neg-
ative setpoint
value blocked
Negative hardware limit
switch reached.
•
Check parametrisa-
tion, wiring and limit
switches.
Config-
urable
43-1
8082
h
Limit switch: pos-
itive setpoint
value blocked
Positive hardware limit
switch reached.
•
Check parametrisa-
tion, wiring and limit
switches.
Config-
urable
43-2
8083
h
Limit switch: pos-
itioning sup-
pressed
–
The drive has left the
intended range of mo-
tion.
–
Technical defect in the
system?
•
Check the intended
range of motion.
Config-
urable
44-0
–
Fault in the cam
disk tables
Cam disk to be started
not available.
•
Check transferred cam
disc no.
•
Correct parametrisa-
tion.
•
Correct programming.
Config-
urable
Содержание CMMP-AS-***-M3 Series