A
Diagnostic messages
108
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
31-1
2311
h
Servo controller
I
@
t
The I
@
t monitoring is re-
sponding frequently.
–
Motor controller does
not have the required
capacity?
–
Mechanics stiff?
•
Check project engin-
eering of the motor
controller,
•
possibly use a more
powerful type.
•
Check the mechanical
system.
Config-
urable
31-0
2312
h
Motor I
@
t
–
Motor blocked?
–
Motor under-sized?
•
Check power dimen-
sioning of drive pack-
age.
Config-
urable
31-2
2313
h
PFC I
@
t
PFC power rating ex-
ceeded.
•
Parameterise opera-
tion without PFC (us-
ing FCT).
Config-
urable
31-3
2314
h
Braking resistor
I
@
t
–
Overloading of the in-
ternal braking resistor.
•
Use external braking
resistor.
•
Reduce resistance
value or use resistor
with higher pulse
load.
Config-
urable
32-0
3280
h
Intermediate cir-
cuit charging time
exceeded
The intermediate circuit
could not be charged
after the mains voltage
was applied.
–
Fuse possibly defect-
ive or
–
Internal braking resist-
or defective or
–
In operation with ex-
ternal resistor, the
resistor is not connec-
ted.
•
Check interface to the
external braking res-
istor.
•
Alternatively, check
whether the jumper
for the internal brak-
ing resistor is in place.
If the interface is correct,
the internal braking res-
istor or the built-in fuse is
probably faulty. On-site
repair is not possible.
Config-
urable
32-1
3281
h
Undervoltage for
active PFC
The PFC cannot be activ-
ated at all until an inter-
mediate circuit voltage of
about 130 VDC is
reached.
•
Check power supply.
Config-
urable
Содержание CMMP-AS-***-M3 Series