A
Diagnostic messages
106
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
29-2
–
MMC/SD card:
parameter set er-
ror
This error is triggered in
the following cases:
–
A load or storage pro-
cess is already run-
ning, but a new load
or storage process is
requested.
DCO file >> Servo
–
The DCO file to be
loaded has not been
found.
–
The DCO file to be
loaded is not appro-
priate for the device.
–
The DCO file to be
loaded is defective.
Servo >> DCO file
–
The memory card is
read-only.
–
Other error while sav-
ing the parameter set
as a DCO file.
–
Error in creating the
file “INFO.TXT”
•
Execute load or stor-
age process again
after waiting 5
seconds.
•
Connect memory card
to a PC and check the
files included.
•
Remove write protec-
tion from the memory
card.
Config-
urable
Содержание CMMP-AS-***-M3 Series