![Festo CMMP-AS-***-M3 Series Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/festo/cmmp-as-m3-series/cmmp-as-m3-series_description_2283123103.webp)
A
Diagnostic messages
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
103
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
26-2
5582
h
Flash:
Flash: Write error
Error when writing the in-
ternal flash memory
•
Execute the last oper-
ation again.
If the error appears again,
the hardware may be
faulty.
PS off
26-3
5583
h
Flash:
Flash: Delete er-
ror
Error during deletion of
the internal flash memory
•
Execute the last oper-
ation again.
If the error appears again,
the hardware may be
faulty.
PS off
26-4
5584
h
Flash:
Flash: Internal
flash error
The default parameter set
is corrupted / data error
in the FLASH area where
the default parameter set
is located.
•
Load firmware again.
If the error appears again,
the hardware may be
faulty.
PS off
26-5
5585
h
Missing calibra-
tion data
Factory-set calibration
parameters incomplete/
corrupted.
This fault cannot be fixed
by the user.
PS off
26-6
5586
h
Missing user pos-
ition data sets
Position data records in-
complete or corrupt.
•
Load factory settings
or
•
save the current para-
meters again so that
the position data is
written again.
PS off
27-0
8611
h
Following error
warning
threshold
Motor overloaded? Check
motor capacity.
Acceleration or braking
ramps are set too steep.
Motor blocked? Commut-
ation angle correct?
•
Check the paramet-
risation of the motor
data.
•
Check parametrisa-
tion of following error
(drag error).
Config-
urable
Содержание CMMP-AS-***-M3 Series
Страница 131: ......