Load firmware via memory card
Procedure for loading firmware via the memory card:
1. Make sure that the output stage enable is switched off.
2. Shift the switch [S3] onto ON.
3. Insert the memory card with the firmware into the module [M1].
4. Actuate the reset button
5. The motor controller checks whether a memory card is plugged in and includes loadable firmware.
Memory card plugged in and valid firmware version
firmware is loaded.
6. The firmware update is signaled through “F.” on the digit representation with 7 segments.
7. The motor controller automatically starts the firmware by triggering a RESET.
8. The motor controller searches for the newest parameter file on the memory card and loads it into
the motor controller.
9. Shift the switch [S3] to ON.
Errors may occur in firmware download. Possible causes for this are:
–
Memory card not plugged in
–
Invalid firmware version
–
Firmware file includes lower case letters
If one of these points is applicable, the firmware update is cancelled and an error reported.
The decimal point in the digit representation with 7 segments is also displayed in case of
errors that were detected or triggered through the bootloader.
If no memory card was found or there is no parameter set on the memory card, the para-
meter set valid before the firmware download is loaded.
If no memory card was found or there is no firmware on the memory card:
–
Error 29-0 is reported
–
The boot process is stopped (displayed through a decimal point on the digit repres-
entation with 7 segments).
It is recommended to have only one firmware file at a time on the SD card. In the case of
several files, the newest one is always loaded!
If the newest file is already included on the motor controller, no firmware update is car-
ried out.
5.2.2
Load parameter set from memory card
Parameterisation in the FCT can establish whether a parameter set is loaded from the memory card
when the motor controller is reset. Possible options:
–
Use the newest parameter file.
–
Load parameter file with specific name.
Loading of the parameter set is shown with a “d” on the digit representation with 7 segments.
Содержание CMMP-AS-***-M3 Series
Страница 131: ......