![Festo CMMP-AS-***-M3 Series Скачать руководство пользователя страница 127](http://html1.mh-extra.com/html/festo/cmmp-as-m3-series/cmmp-as-m3-series_description_2283123127.webp)
A
Diagnostic messages
Festo – GDCP-CMMP-M3-FW-EN – 1203NH
127
Diagnostic messages of the CMMP-AS-...-M3
No.
Reaction
Actions
Causes
Message
Code
90-9
5080
h
Illegal firmware
version
A development version
compiled for the debug-
ger was loaded as nor-
mal.
Check the firmware ver-
sion, and update the firm-
ware if necessary.
PS off
91-1
–
Memory error
when copying
Firmware parts were not
copied correctly from the
external FLASH into the
internal RAM.
Switch on the device
again (24V). If the error
occurs repeatedly, check
the firmware version and
update the firmware if ne-
cessary.
PS off
91-2
–
Error when read-
ing the control-
ler/power section
coding
The ID-EEPROM in the
controller or power sec-
tion could either not be
addressed at all or does
not have consistent data.
Switch on the device
again (24V). If the error
occurs repeatedly, the
hardware is faulty. No re-
pair possible.
PS off
91-3
–
Software initial-
isation error
One of the following com-
ponents is missing or
could not be initialised:
a) Shared memory not
available or defective
b) Driver library not avail-
able or defective
Check firmware design,
update if necessary
PS off
91-0
6000
h
Processor error
Internal SRAM too small
for the compiled firm-
ware. Can only occur with
beta versions.
Check the firmware ver-
sion, and update the firm-
ware if necessary.
PS off
Tab. A.2
Diagnostic messages CMMP-AS-...-M3
Содержание CMMP-AS-***-M3 Series
Страница 131: ......