Monitoring of the actuator behaviour
The actuator characteristics can be monitored and controlled by messages and comparators. Further
more, the motor controller has internal protection functions, e.g. to protect internal components from
damage in the event of operator error.
2.7.1
Dispatches
Messages become enabled if the target value is within a tolerance window for a defined period of time.
Messages can be output by means of configurable, digital outputs.
Message
Brief description
Profile
Motion Complete (target
recognition)
signals the end of an order that was started by record
selection.
Valve
Binary
Monitoring of following
errors (2F
h
)
monitors the closed-loop control characteristics while
an order is in positioning and velocity mode
(
è
Binary
Standstill monitoring
(37
h
in closed-loop operation, monitors the characteristics
after Motion Complete, Stop or Pause (
è
Binary
1)
The error management functionality of FCT makes it possible to parameterise the response to this message (
è
FCT error
management).
Tab. 2.55 Dispatches
“Motion Complete” message
“Motion Complete” signals the end of an order. A window is defined for each order type (position,
velocity or force mode). As soon as the actual value of the target parameter is in the time window for
the duration of the parameterised damping time, the Motion Complete message (order ended) is
triggered.
Motion Complete
t
t
v
t1
1
2
3
t1: Damping time, Motion Complete
1
Actual speed
2
Setpoint speed
3
Time window, Motion Complete
Fig. 2.12 Motion Complete – example of velocity mode