2
Product description
44
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
2.5.5
Stopping
Function
Description
Profile
Halt
(STOP)
Aborting the current set of commands
–
The actuator is braked down to a stop using the retardation
set of commands
After braking to a standstill:
–
Open-loop operation: the drive is held at the position
reached by the holding current setting.
–
Closed-loop operation: the actuator remains stationary and
position-controlled at the position reached. Standstill mon
itoring is activated.
–
Motion complete is set.
Valve
Binary
Pause
(PAUSE)
Interruption to the current set of commands
–
The actuator is braked down to a stop using the retardation
set of commands.
After braking to a standstill:
–
Open-loop operation: the drive is held at the position
reached by the holding current setting.
–
Closed-loop operation: the actuator remains stationary and
position-controlled at the position reached. Standstill mon
itoring is activated.
–
Motion complete is
not
set.
Continued
–
The order can be continued using the corresponding signal
to the control interface.
Delete remaining path:
–
The remaining path can be deleted using the corresponding
signal to the control interface.
–
Motion complete is set.
Binary
1)
Parameterisation of record retardation under FCT [...][Axis][Record Table]
Tab. 2.37 Stopping actuator
Quick Stop by removal of controller enable
Through removal of controller enable, the current actuator function can be terminated.
After braking to a stop with the parameterised Quick-Stop retardation function, the
closed-loop controller is blocked. The actuator is not controlled after this.