![Festo CMMO-ST-C5-1-DION Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/festo/cmmo-st-c5-1-dion/cmmo-st-c5-1-dion_original-instructions-manual_2283101128.webp)
6
Diagnostics
128
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
Diagnostic messages and fault clearance
06h
Encoder
Definable as:
F
/-/-
Diagnostic memory: always
An error has occurred during evaluation of the encoder. The current position values may be incorrect.
Check encoder cable and connection for short-circuits, breaks or incorrect pin assignment.
Conduct a software reset with a commutation angle search and homing procedure.
If the error is still present, the hardware (encoder) may be defective.
– Resettable: Cannot be reset; software reset is necessary.
Definable error reaction(s): A
09h
Offset determination for current measurement
Definable as:
F
/-/-
Diagnostic memory: always
An error has occurred during initialisation of the current measurement.
Perform a software reset.
– Resettable: Cannot be reset; software reset is necessary.
Definable error reaction(s): A
0Ah
General error
Definable as:
F
/-/-
Diagnostic memory: always
An internal error has occurred.
Restart device. If the error occurs frequently, contact Festo Service.
– Resettable: Error can be reset immediately.
Definable error response(s): B
0Bh
Parameter file invalid
Definable as:
F
/-/-
Diagnostic memory: always
No valid parameter set stored. After creation of the parameter file, a firmware update is performed, if
necessary: As much data as possible is automatically loaded from the parameter file. Parameters
that are not initialised by the parameter file are loaded from the default parameter file.
Enter a valid parameter set in the device. If the error is still present, the hardware may be defect
ive.
– Resettable: Error can be reset immediately.
Definable error reaction(s): A
0Ch
Firmware update execution error
Definable as:
F
/-/-
Diagnostic memory: optional
The firmware update has not been properly executed or completed.
Check Ethernet connection between device and PC. Restart device and perform the firmware up
date again. Check whether valid firmware has been selected for the device. The previous firmware
version remains active until the firmware update has been successfully completed. If this error is
still present, the hardware may be defective.
– Resettable: Cannot be reset; software reset is necessary.
Definable error reaction(s): A